Kirby Morgan Air Control System 5
Operations and Maintenance Manual
KMDSI
1430 Jason Way
Santa Maria, California
United States of America
Postal Code 93455
Telephone (805) 928-7772
Fax (805) 928-0342
Kirby Morgan Air Control System 5, KMACS 5,
Dive Control System-2A, DCS-2A, DCS-3 and DCS-1 are trademarks of KMDSI .
Use of these terms to describe products that are not manufactured by KMDSI is not permitted
Manual prepared by Marine Marketing and Consulting & KMDSI .
© 2003 KMDSI Document # 041112001
K
I
R
B
Y
M
O
R
G
A
N
D
I
V
E
S
Y
S
T
E
M
S
,
I
n
c
.
Part # 100-075
Zobrazit stránku 0
1 2 3 4 5 6 ... 30 31

Shrnutí obsahu

Strany 1 - Part # 100-075

Kirby Morgan Air Control System 5Operations and Maintenance ManualKMDSI 1430 Jason Way Santa Maria, CaliforniaUnited States of AmericaPostal Code 9345

Strany 2 - This page not used

4KMACS 5 MANUAL© 2003 KMDSI Document # 041112001the electronic components. The KMACS 5 should be treated as you would any expensive life support equi

Strany 3

5KMACS 5 MANUAL© 2003 KMDSI Document # 0411120016. ORANGE AIR SUPPLY FLOW INDICATOR LINESThe “ORANGE” air supply flow indicator line indicates

Strany 4 - Warranty Information

6KMACS 5 MANUAL© 2003 KMDSI Document # 0411120018. BLUE BREATHING AIR SUPPLY PRESSURE GAUGE (M)The Blue pressure gauge (M) indicates the pres-s

Strany 5 - Table of Contents

7KMACS 5 MANUAL© 2003 KMDSI Document # 04111200113. REGULATOR ADJUSTMENT KNOB FOR UMBILICAL PRESSURE (H)The regulator Adjustment Knob (H) allow

Strany 6

8KMACS 5 MANUAL© 2003 KMDSI Document # 0411120012.2 FIRST USE OF THE KMACS 5Place the Dive Control System on a firm surface. The KMDSI logo should be

Strany 7 - GENERAL INFORMATION

9KMACS 5 MANUAL© 2003 KMDSI Document # 041112001excessive force to the knobs; air pressure from the tanks will create a good seal. Be sure the bleed

Strany 8

10KMACS 5 MANUAL© 2003 KMDSI Document # 041112001hoses to the mask or helmet, (refer to the manual for the mask or helmet for the proper connection p

Strany 9

11KMACS 5 MANUAL© 2003 KMDSI Document # 0411120012.5.2 TESTING COMMUNICATIONSTest the communications between the diver and the KMACS 5. With the com

Strany 10 - KMACS 5 MANUAL

12KMACS 5 MANUAL© 2003 KMDSI Document # 0411120012.5.3 TESTING THE PNEUMOThe pneumo supply may be tested in either the high pressure supply mode or

Strany 11

13KMACS 5 MANUAL© 2003 KMDSI Document # 041112001The dive supervisor may not always be the KMACS 5 operator. The dive supervisor may want or need th

Strany 12

This page not used

Strany 13

14KMACS 5 MANUAL© 2003 KMDSI Document # 041112001reading of the bottom depth. In an emergency, the pneumo air can be used as a breathing air supply f

Strany 14 - OPERATING INSTRUCTIONS

15KMACS 5 MANUAL© 2003 KMDSI Document # 041112001inform top side that he is, “Leaving the bottom.” The KMACS 5 operator should carefully note the ti

Strany 15

16KMACS 5 MANUAL© 2003 KMDSI Document # 041112001Section 3.0KMACS 5 Maintenance The KMACS 5 requires very little user maintenance. With proper care,

Strany 16

17KMACS 5 MANUAL© 2003 KMDSI Document # 041112001Section 4.0Trouble Shooting the KMACS 5 System4.1 GENERALThe KMACS 5 is an extremely simple system

Strany 17

18KMACS 5 MANUAL© 2003 KMDSI Document # 0411120014.3 NO PNEUMO READING Symptoms1) No air to diver’s end of pneumo2) Gauge reads sustained pressure at

Strany 18

19KMACS 5 MANUAL© 2003 KMDSI Document # 041112001 6) Air can be heard escaping into console interior.7) Umbilical hose pressure and supply press

Strany 19

20KMACS 5 MANUAL© 2003 KMDSI Document # 041112001# of Pulls 3 4 From Tender to Diver“Stand by to come up” “Come up” From Diver to Tender “Ta

Strany 20

21KMACS 5 MANUAL© 2003 KMDSI Document # 041112001 KMACS 5 EXPLODED VIEWS & PARTS LISTSKey# Part # Description1 530-017 S

Strany 21

22KMACS 5 MANUAL© 2003 KMDSI Document # 041112001Key# Part # DescriptionPanel Mounted Plumbing and Gauges© 2001 KMDSI Document # 0109250011

Strany 22 - KMACS 5 Maintenance

23KMACS 5 MANUAL© 2003 KMDSI Document # 041112001Key# Part # Description Key# Part # Description 1 455-024 Connector, L.P. 2

Strany 23 - Section 4.0

Definitions of Signal WordsUsed in this ManualDANGER: This word indicates an imminently hazardous situation, which if not avoided, will result in death

Strany 24

24KMACS 5 MANUAL© 2003 KMDSI Document # 041112001KMACS 5 DIVE LOGDiver: Date:KMACS 5 Operator:Dive Location:Weather Conditions:Purpos

Strany 25

25KMACS 5 MANUAL© 2003 KMDSI Document # 041112001Table of EquivalentsTo convert units appearing in Column 1 (left column) into equivalent values in

Strany 26

Warranty InformationKMDSI warrants every new mask, helmet, SCUBA regulator or air control system (KMACS) (each, a Product) to be free from defects in

Strany 27 - Communications Panel

Table of ContentsSection Title Page # 1.0 General Information 1 1.1 Definitions 1 1.2

Strany 28 - Plumbing and Gauges

Kirby Morgan Air Control System 5 with communications.Kirby Morgan Air Control System 5 with no communications.

Strany 29

1KMACS 5 MANUAL© 2003 KMDSI Document # 041112001Section 1.0 High Pressure (H.P.) Hose: A flexible hose de-signed to carry a working pressu

Strany 30 - KMACS 5 DIVE LOG

2KMACS 5 MANUAL© 2003 KMDSI Document # 041112001to “suit” the term “dressed-in” has remained to describe putting the suit on. A diver who is “

Strany 31 - Table of Equivalents

3KMACS 5 MANUAL© 2003 KMDSI Document # 041112001CAUTION: Although the high pressure gauges on the KMACS 5 are rated to 5000 psi (345 bars), t

Komentáře k této Příručce